FROM specification:
Joiner Work, 细木作
The joiner work shall be carried out in accordance with the class rules. 木作安装须符合船级相关规定。
In general, the main electrical cables, vent ducts, piping, which are fitted in cabins, offices ,and public rooms to be concealed behind linings and ceilings.一般地,主干电缆、风管等管道须在舱室等装配好。在公共场所须隐藏在衬板和天花板下。
Clear height in the living quarters to be min 2.1 m (except private sanitary spaces which
are 2.05m) from the top of floor covering to the bottom of overhead ceiling or to that of
ventilating trunk where no ceiling is applied, except protruding part such as ceiling lamp,
ventilating louver and unavoidable corner bracket, etc.在住舱空间净高最小2.1M,(私人卫生间除外(2.05M)),从地板敷料上到天花板敷料下的距离~(净高)。除去突出部分如吊灯、通风栅和不可避免的角托架等~~~