发表于 2015-12-7 22:36
|
显示全部楼层
来自: 中国浙江宁波
本帖最后由 godwingx 于 2015-12-8 16:59 编辑
在RESOLUTION MSC.333(90)里是这样写的
5.5.10 Main alarms
This should include the status of all mandatory alarms on the bridge 2 or as received from the Bridge Alert Management System, if installed, recorded as individually identified alarms.
__________
2 Resolution A.1021(26), Code on Alerts and Indicators, 2009, table 10.1.1.
也就是说按Resolution A.1021(26), Code on Alerts and Indicators, 2009, table 10.1.1所要求的所有桥楼强制报警都视为是main alarm。
而在Resolution A.1021(26), Code on Alerts and Indicators, 2009, table 10.1.1里,主机shut down override的要求是有indication/indicator,不是alarm,机舱死人报警是要求要有alarm的。
然后关于主机shut down override,还要再参照下面这条,
5.5.12 Engine and thruster order and response
This should include the positions of any engine telegraphs or direct engine/propeller controls and feedback indications on the bridge, if fitted, including ahead/astern indicators and indicate the control station in use. This should also include any thrusters if fitted and indicate the control station in use.
综上所述,都要接入VDR。
|
|