1.3 The location of the emergency source of electrical power and associated transforming equipment, if
any, the transitional source of emergency power, the emergency switchboard and the emergency electric
lighting switchboards in relation to the main source of electrical power, associated transforming equipment,
if any, and the main switchboard shall be such as to ensure to the satisfaction of the Administration that a
fire or other casualty in spaces containing the main source of electrical power, associated transforming
equipment, if any, and the main switchboard or in any machinery space of category A will not interfere
with the supply, control and distribution of emergency electrical power. As far as practicable, the space
containing the emergency source of electrical power, associated transforming equipment, if any, the
transitional source of emergency electrical power and the emergency switchboard shall not be contiguousto the boundaries of machinery spaces of category A or those spaces containing the main source of electrical
power, associated transforming equipment, if any, or the main switchboard. |
|