1) Start emergency genset by use of manually hydraulic pump(not by the storage battery).
2) Emergency generator on bus of emergency switchboard.
3) Manually start Em'cy air compressor - filling aux. air receiver with air of abt 15 bar
pressure with which A/E can start.
4) Start No. 1 main genset at minimum required starting air pressure(about 12 bar)
5) No. 1/2 starting air compressors are to be set at auto. operating mode two(2)
sets of air compressor are to be run in parallel. and filled air to one main receiver.
6) Start essential pumps and E/R fans. steering gear.
7) Start main engine at min. required start air pressure (about 12 bar) from engine
control console.
Record the taking time for the above mentioned each steps of operating.
The mainengine should be started within 30 min. |
|