The mass of all portable fire extinguisher shall not exceed 23kg, and they shall have a fire-extinguishing capability at least equivalent to that of a 9l fluid extinguisher.
所有手提式灭火器的重量应不超过23公斤,且其灭火容量至少应等同于9公升流体灭火器。
The volume of starting air receivers, converted to free air volume, shall be added to the gross volume of the machinery space when calculating the necessary quantity of extinguishing medium.
计算灭火剂的必要剂量时,起动空气瓶的容积,换算成大气体积,加上机舱处所的总容积。
40% of the gross volume of the largest machinery space so protected, the volume to exclude that part of the casing above the level at which of the horizontal area of the casing is 40% or less of the horizontal area of the space concerned taken midway between the tank top and the lowest part of the casing or
最大机舱处所总容积的40%受到保护,其容积不包括:机舱棚水平面积为40%处的水平线以上部分,或小于双层底板至机舱棚最低部位之间的中间点所涉及空间的水平面积的水平线以上部分。