控制位置在机舱以外,而不是集控室。
2.2.2 Means of control shall be provided for stopping ventilating fans. Controls provided for the power
ventilation serving machinery spaces shall be grouped so as to be operable from two positions, one of which
shall be outside such spaces. The means provided for stopping the power ventilation of the machinery
spaces shall be entirely separate from the means provided for stopping ventilation of other spaces.
2.2.3 Means of control shall be provided for stopping forced and induced draught fans, oil fuel transfer
pumps, oil fuel unit pumps, lubricating oil service pumps, thermal oil circulating pumps and oil separators
(purifiers). However, paragraphs 2.2.4 and 2.2.5 need not apply to oily water separators.
2.2.4 The controls required in paragraphs 2.2.1 to 2.2.3 and in regulation 4.2.2.3.4 shall be located outside
the space concerned so they will not be cut off in the event of fire in the space they serve. |
|