发表于 2010-6-24 15:48
|
显示全部楼层
来自: 中国上海
A collision bulkhead is to be fitted which is to be
watertight up to the freeboard deck. This bulkhead is to be
located at a distance from the forward perpendicular FP of
not less than 5 per cent of the length L of the ship or 10 m,
whichever is the less, and not more than 8 per cent of L.For ships not covered by the SOLAS Convention, the length
L need not be taken less than 50 m, unless required by the
National Authorities.
2.1.2 Where any part of the ship below the waterline
extends forward of the forward perpendicular, e.g. a bulbous
bow, the distances, in metres, stipulated in [2.1.1] are
to be measured from a point either:
• at the midlength of such extension, or
• at a distance 1,5 per cent of the length Lof the ship
forward of the forward perpendicular, or
• at a distance 3 metres forward of the forward perpendicular;
whichever gives the smallest measurement.
2.1.3 The bulkhead may have steps or recesses provided
they are within the limits prescribed in [2.1.1] or [2.1.2].
No door, manhole, ventilation duct or any other opening is
to be fitted in this bulkhead. |
|