查看: 2651|回复: 3
收起左侧

[SOLAS] 散货船风机接口柔性风管是否满足SOLAS要求?

[复制链接]
发表于 2012-12-24 10:48 | 显示全部楼层 |阅读模式 来自: 中国天津
按SOLAS2012的要求,风管要求用钢制材料,在一些特定条件下可以用不燃材料,现船检要求将散货船机舱、上建、艏楼内所有帆布接头更换,请问船检对规范的理解是否全面,望高手解答。
回复

使用道具 举报

龙船学院
发表于 2012-12-24 18:38 | 显示全部楼层 来自: 新加坡
柔性风管必须是不燃或防燃材料,而且厂家应该出ABS approved cert.
回复 支持 反对

使用道具 举报

 楼主| 发表于 2012-12-25 08:57 | 显示全部楼层 来自: 中国天津
hanyuxiang 发表于 2012-12-24 18:38
柔性风管必须是不燃或防燃材料,而且厂家应该出ABS approved cert.

Chapter II-2, Part C SOLAS 74/78 page 60/112
short length of duct, not in general exceeding 0.02m2 in free cross-sectional area nor 2 m in length, need not be steel or equivalent provided that all of the following conditions are met:
.3.1 subject to paragraph 7.4.4.3.2 the duct is constructed of any material which has low flame spread characteristics;
3.2 on ships constructed on or after 1 July 2010, the ducts shall be made of heat resisting noncombustible material, which my be faced internally and externally with membrances having low flame-spread characteristics and, in each case, a calorific* value not exceeding 45 MJ/m2 of their surface area for the thickness used;
.3.3 the duct is used only at the terminal end of the ventilation system; and
3.4 the duct is not located closer than 600mm measured along its length to a penetration of an "A" or "B" class division, including continuous "B" class ceilings.

steel or equivalent 并没有要求一定是钢质的,防火帆布是不是EQUIVALENT?

回复 支持 反对

使用道具 举报

发表于 2012-12-25 20:57 | 显示全部楼层 来自: 中国山东青岛
yhj1081 发表于 2012-12-25 08:57
Chapter II-2, Part C SOLAS 74/78 page 60/112
short length of duct, not in general exceeding 0.02m ...

出发点是对的, 如何证明防火帆布满足上述要求? 如果有详细材料说明,我觉得是可以的。 SOLAS这里面没有说明要Administration approve,也没有引申系列的决议或通函解释,所以厂家的材料证书应该可以
回复 支持 反对