回复 1# andes
细看DNV规范,Pt.4 Ch.8 Sec.10,Table B1 Enclosure types in relation to location,电气设备首先考虑index of protection(DNV规范中称作Enclosure types),就是IP防护等级,Socket outlet在大多数open deck都是IP56,但是备注中提到,IP 44 may be accepted, when placed in a box giving additional protection against ingress of water. Equipment for control and indication of watertight doors and hatches shall have watertightness based on the water pressure that may occur at the location of the component, if intrusion of water can affect the control or indication system.
其次对于你提到的油船,化学品船,液化气船,请参照危险区域划分图,zone 0,zone 1和zone 2,然后根据规范Pt.4 Ch.8 Sec.11,选择防爆等级Ex。 |
|