船舶设备并网谐波要求

[复制链接]
发表于 2019-5-3 11:21 | 显示全部楼层 |阅读模式 来自: 中国上海
想请教大神们有没有规范指南等限制船舶电力设备的并网谐波总含量以及各次谐波含量的限制。
回复

使用道具 举报

龙船学院
发表于 2019-5-5 09:01 | 显示全部楼层 来自: 中国北京
我不确定你说的并网是不是指整个电网。
每个船级社海船规范里面都有,参见ABS:
The total harmonic distortion (THD) in the voltage waveform in the distribution systems is not to exceed 8% and any single order harmonics not to exceed 5%. Other higher values may be accepted provided the distribution equipment and consumers are designed to operate at the higher limits. This relaxation on THD limits is to be documented (harmonic distortion calculation report) and made available on board as a reference for the Surveyor at each periodical survey. Where higher values of harmonic distortion are expected, any other possible effects, such as additional heat losses in machines, network resonances, errors in control and monitoring systems are to be considered. See also 4-8-2/9.22 and 4-8-2/9.23.
回复 支持 反对

使用道具 举报

 楼主| 发表于 2019-5-6 22:47 | 显示全部楼层 来自: 中国上海
谢谢,我在船舶设计手册电气分册里面也找到了一些要求,谢谢分享
回复 支持 反对