如果是helideck 请见下面的规格书 略作参考,如果是海上飞机场 我没听过,下面的请略过
helideck
General
A helideck forward shall be constructed partly on top of the accommodation block and suitable for operations with Sikorsky S92 type of helicopter. The deck will be arranged at the forward side of the vessel supported by a dedicated structure. The supporting structure will be of lattice type with foundations integrated in the accommodation deckhouse.
The helideck will be designed, fabricated and marked in accordance with Class and relevant Civil Aviation Authority rules (CAP 437).
The deck will be of welded Steel construction of stiffened plate.
The helideck will have a non-slip painted surface, a landing net, and markings in contrasting colors, beacons, flood lights and wind sock, all in accordance with the requirement o f the Regulatory Bodies.
The helideck shall not have refueling capability.
A helicopter reception room with toilet cubicle is located on the wheelhouse top aft of the helideck.
Safety Provisions
Two ways of escape will be provided as far apart as possible within the present configuration.
The deck will be surrounded by a drain gutter and a safety net of 1.50 m in width. The gutter will be fitted with adequate drain points, connected to drain pipes, which will be extended to the level below the forecastle deck.
The helideck will have recessed tie-down points for the helicopter. The recessed tie-down points will be connected to the drain pipes. At the helideck edges surface type eye lugs will be provide for the helideck net.
One (1) set of rescue equipment for helideck will be provided in a fiberglass box.
Fire Fighting System
A foam fighting system will be provided in compliance with requirement of CAP 437 and Regulatory Bodies.
Furthermore two (2) trolley-mounted 22kg CO2 extinguisher with an extended applicator will be supplied, and two (2) 50 kg wheeled dry power extinguishers located at each main access to the helideck. |
|