关于机舱进水时间的计算
DNV规范里有如下要求:401 The location of the controls of any valve serving a sea inlet,
a discharge below the waterline or a bilge injection system
shall be so sited as to allow adequate time for operation in case
of influx of water to the space, having regard to the time likely to
be required in order to reach and operate such controls. If the level
to which the space could become flooded with the ship in the
fully loaded condition so requires, arrangements shall be made to
operate the controls from a position above such level.
(SOLAS Ch. II-1/48.3)
402 If it can be documented by calculation of filling time that
the water level is not above the tank top floor after 10 minutes
from the initiation of the uppermost bilge level alarm, it will be
accepted that the valves are operated from the tanktop floor.
Guidance note:
Various Flag Administrations have worked out their own interpretations
of this regulation.
---e-n-d---of---G-u-i-d-a-n-c-e---n-o-t-e---
有谁有相关的计算公式?或计算方法。 allow adequate time 通常取多少? 10分钟?或者5分钟来得及吗? the time required is very flexible, to see how long time we can get first. 10分钟 半小时吧?
计算方法 708的设计手册里面不是有吗? 708的设计手册里相关计算方法 内容能提供吗? 原帖由 chin_bingjun 于 2009-1-14 12:48 发表 https://www.imarine.cn/bbs/images/common/back.gif
708的设计手册里相关计算方法 内容能提供吗?
你没有708的设计手册?大侠。
没有的话,我发给你
回复 7楼 DraftMan 的帖子
我没有yuanjiong1985@163.com 来份谢谢啊~ 原帖由 DraftMan 于 2009-1-14 13:03 发表 https://www.imarine.cn/bbs/images/common/back.gif
你没有708的设计手册?大侠。
没有的话,我发给你
发好了吗?发完了我去那边学学.
708的那本和国防科技出版的那本就什么区别吗? DNV通常都是按照10分钟来要求的! 不好意思,刚才找了一下,没看到了。 原帖由 billy 于 2009-1-14 13:35 发表 https://www.imarine.cn/bbs/images/common/back.gif
发好了吗?发完了我去那边学学.
708的那本和国防科技出版的那本就什么区别吗?
区别还是有的,比如机舱浸水时间的计算,国防科技出版的就没有 我也没有麻烦你发发,谢谢
wby918@126.com 问题以解决,船舶设计手册轮机分册里找到了。 10分钟啊 楼主,找到了答案给大家贴出来作为这个主题的结束不是更好吗? 好的。见附件 这个一定要顶,我正在找这个,谢谢LZ啊 虽然看不太懂 但是还是学到不少东西。哈哈 设计手册的东西不能作为依据,去看具体的规范的要求。